Proteksi Arus Netral dan Suhu Transformator Berbasis IoT Dampak Beban Tidak Seimbang
DOI:
https://doi.org/10.33795/elposys.v12i2.6207Keywords:
Neutral Current, Unbalanced Load, Body Temperature, TelegramAbstract
Current imbalance results in neutral current and an increase in the temperature of the distribution transformer body. Due to the large number and scattered locations, maintenance of the transformers is carried out at least three times a year. Therefore, the authors developed a laboratory-scale device, which is a miniature neutral current and temperature increase protection system based on the Internet of Things (IoT). The results from the laboratory-scale testing of this protection system will disconnect the load when the current imbalance reaches ≥25% and the body temperature reaches ≥90˚C. Notifications will be sent to Telegram if the load current imbalance is in the range of 10%-14% (sufficient), 15%-24% (insufficient), and ≥25% (poor), and temperatures of 83-84℃ (sufficient), 85-89℃ (insufficient), and ≥90℃ (poor). The miniature protection can disconnect the load when the imbalance value is 25.92% and the temperature reaches 90˚C. Monitoring data is stored in a logger and can be downloaded. Thus, this tool can enhance reliability and help PLN personnel work more effectively.
References
A. P. Purnomoadi, H. S. Purnomo, A. S. Habibie, N. E. Saputro, D. R. Jintaka, dan I. M. Sari, “A Review on Asset Health Management and Criticality Parameters in PLN Indonesia,” dalam A Preliminary Review on Asset Health Management and Criticality Parameters in PLN Indonesia, Institute of Electrical and Electronics Engineers Inc., 2022. doi: 10.1109/ICPERE56870.2022.10037534.
M. D. T. Sogen, “ANALISIS PENGARUH KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN LOSSES PADA TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO) AREA SORONG,” Jurnal Electro Lucent , vol. 4, no. 1, hlm. 1–10, 2018.
A. B. Prayoga dan B. Suprianto, “Analisis Pengaruh Ketidakseimbangan Beban Pada Transformator Distribusi Terhadap Rugi Daya (Losses) Dengan Digsilent Power Factory di PT. PLN (Persero) ULP Ngunut,” Jurnal Teknik Elektro., vol. 12, no. 02, hlm. 23–32, 2023.
H. Muchtar dan Y. Sopian, “STUDI VERIFIKASI SISTEM KETIDAKSEIMBANGAN BEBAN PADA JARINGAN TEGANGAN RENDAH MENGGUNAKAN ALAT PHB – SR (PERALATAN HUBUNG BAGI SAMBUNGAN RUMAH) DI WILAYAH PLN AREA CEMPAKA PUTIH,” elektum, vol. 14, no. 1, hlm. 1, Apr 2017, doi: 10.24853/elektum.14.1.1-8.
R. A Duyo dan A. Sulkifli, “ANALISIS JARINGAN DAN PEMELIHARAAN PADA JARINGAN DISTRIBUSI DI PT.PLN WILAYAH CABANG PINRANG,” VERTEX ELEKTRO, vol. 01, no. 02, hlm. 1–11, 2019.
S. Hidayat dkk., “PENYEIMBANGAN BEBAN PADA JARINGAN TEGANGAN RENDAH GARDU DISTRIBUSI CD 33 PENYULANG SAWAH DI PT PLN (PERSERO) AREA BINTARO,” Jurnal Sutet, vol. 8, no. 1, hlm. 21–27, 2018.
G. F. A. Yudhistira, S. Sutedjo, dan R. Rakhmawati, “Distribution Transformer Secondary Bushing Temperature Detection Device using Feed Forward Neural Network,” ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika, vol. 11, no. 4, hlm. 983–997, Okt 2023, doi: 10.26760/elkomika.v11i4.983.
S. Muhammad, Hamdani, dan Beni Satria, “Sistem Ketidak Seimbangan Beban Pada Jaringan Tegangan Rendah Menggunakan Alat PHB – SR ( Peralatan Hubung Bagi Sambungan Rumah ) Di PT. PLN Persero ULP Binjai Timur,” JurnalOrangElektro, vol. 13, no. 2, 2024.
Syukri, T. M. Asyadi, Mauliadi, dan F. Moesnadi, “Analisa Pembebanan Transformator Distribusi 20 kV Pada Penyulang LS5 Gardu LSA 249,” JJEEE, vol. 4, no. 2, Jul 2022.
A. Saiful Aprilian Ektianto, I. M. Agus Darwanto Sekolah Tinggi Teknologi Ronggolawe Cepu, dan P. Korespondensi, “ANALISIS KETIDAK SEIMBANGAN BEBAN PADA TRANSFORMATOR DISTRIBUSI Di PT. PLN (Persero) RAYON CEPU,” 2021.
Z. Sya’roni dan T. Rijanto, “ANALISIS KETIDAKSEIMBANGAN BEBAN TRANSFORMATOR DISTRIBUSI 20 KV DAN SOLUSINYA PADA JARINGAN TEGANGAN RENDAH,” JurnalTeknikElektro, vol. 08, no. 01, hlm. 173–180, 2019.
K. Rohmat dan M. Riyadi, “ANALISIS KETIDAKSEIMBANGAN BEBAN TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO) UPDL PANDAAN,” Transmisi: Jurnal Ilmiah Teknik Elektro, vol. 25, no. 4, hlm. 186–192, Des 2023, doi: 10.14710/transmisi.25.4.186-192.
T. Setiawan, Syukri, dan Muliadi, “Kajian Pemeliharaan Trafo Distribusi Menggunakan Metode Codition Based Maintenance (CBM),” Aceh Journal of Electrical Engineering and Technology, vol. 2, no. 2, hlm. 18–23, 2022.
Ruliyanto, “Pengaruh Ketidakseimbangan Beban Terhadap Arus Netral dan Arus Ground pada Trafo 1 dan Trafo 2 pada Beban Puncak Sesaat,” Jurnal Ilmiah GIGA, vol. 23, no. 1, hlm. 27–34, 2020.
H. L. Latupeirissa, “PENGARUH KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN LOSSES DAYA PADA TRAFO DISTRIBUSI GARDU KP-01 DESA HATIVE KECIL,” JURNAL SIMETRIK, vol. 7, no. 2, hlm. 16–22, 2017.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Elposys: Jurnal Sistem Kelistrikan

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.